Home > File Status > File Error 35 Cobol

File Error 35 Cobol

Contents

END-IF format to make it clear, instead of using full-stops. CPF5116, CPF5018, CPF5272 if organization is sequential. 5 An OPEN statement with the INPUT, I-O, or EXTEND phrase was attempted on a non-optional file that was not present. Robert Sample Global moderator Posts: 3110Joined: Sat Dec 19, 2009 8:32 pmLocation: Bellevue, Iowa Hasthanked: 1 time Beenthanked: 181 times Top Re: VSAM Error - 35 --- OPEN ERROR NOT We appreciate hearing from you. Check This Out

This can be caused by issuing a read after the end-of-file has been reached during sequential processing. 9149 95 Wrong open mode or access mode for REWRITE/ DELETE. 9150 96 Program This does not apply to VSAM sequential files. 06 WRITE Attempted to write to a file that has been opened for INPUT. 07 CLOSE OPEN RT016 Too many device files open. Resource owned by another program, or unavailable. (9H is the result when an ACQUIRE operation causes any of the OS/400 exceptions monitored for 90, or 9N to occur.) I WRITE operation

File Status 90 In Cobol

If opened I-O the file was created. Attempt has been made to store a record that would create a duplicate key in the indexed or relative file OR a duplicate alternate record key that does not allow duplicates. TELA. RT161 File header not found.

Regards,Nanthu.Y. Should I use "Does" or "Is" in this question? Indicates a sequence error. File Status In Cobol Example If status-key-1 is equal to 9 then status-key-2 is a one byte, binary value as defined in the following table.

In this case, the physical size of the new record is allowed to be smaller than that of the record being replaced. 46 A sequential READ operation has been tried on CPF5001, CPF5006, CPF5013, CPF5020, CPF5025. 4 An attempt was made to write beyond the externally defined boundaries of a relative or indexed file. The last I/O statement executed for the file, before the execution of a DELETE or REWRITE statement, was not a READ statement. 44 A boundary violation exists. Error description When extracting the catalog RBA LE/COBOL fails FS=35 ON VSAM ESDS FILE (defined for REUSE).

An attempt has been made to access a record, identified by a key, and that record does not exist in the file. File Status 37 In Vsam If you get a 30 again after all that, you get a BIG FAT LOOP. RT047 Indexed structure overflow. (Could indicate that you have reached the maximum number of duplicate keys.) RT065 File locked. Use CONTINUE instead of NEXT SENTENCE.

Cobol Error Codes Mainframe

StatusKey-1Description by Group 0Successful Completion or non-terminal condition that may be acceptable to continue processing. Página creada en Junio de 1.998, con el proposito de difundir el lenguaje Cobol en nuestra lengua. Andres Montes [98/11] File Status 90 In Cobol I checked on the internet what it is this status, and from what I understand is that the system does not find the file, but I created the file in the Cobol Abend Codes Explore the Assembler Connection for more examples of mainframe Assembler programming techniques and sample code.

For QSAM file: An OPEN statement with the OUTPUT phrase was attempted, or an OPEN statement with the I-O or EXTEND phrase was attempted for an optional file, but no DD his comment is here The following tables contain file-status-key content that may be set by Micro Focus COBOL (Mainframe Express or Net Express) or an IBM Mainframe System (MVS, OS/390 or ZOS). H ACQUIRE operation failed. RT010 File name not supplied. File Status 39

Status1 & 2 Description 00 Successful completion 02 Indexed files only. Extended file status codes have the following format: 9/nnn where nnn is a binary (COMP-X) number, equivalent to a run-time error number. The leading zero of the status field being the success codes. this contact form Possible violations are: The EXTEND or OUTPUT phrase was specified but the file would not support write operations.

We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms. File Status 92 Alternatively a START or READ operation has been tried on an optional input file that is not present. 24 Relative and indexed files only. Wife sent to collections for ticket she paid ten years ago How do you solve the copied consciousness conundrum without killing anyone?

Robert Sample Global moderator Posts: 3110Joined: Sat Dec 19, 2009 8:32 pmLocation: Bellevue, Iowa Hasthanked: 1 time Beenthanked: 181 times Top Display posts from previous: All posts1 day7 days2 weeks1

Temporary fix Comments APAR Information APAR numberPM52367 Reported component nameLE COBOL+JAP+CI Reported component ID5686CF836 Reported release02W StatusCLOSED PER PENoPE HIPERYesHIPER Special AttentionNoSpecatt / Xsystem Submitted date2011-11-16 Closed date2011-11-22 Last modified date2012-11-29 SimoTime Services has experience in moving or sharing data or application processing across a variety of systems. RT005 Illegal device specification. File Status Codes In Cobol Pdf CPF5184.

We have not set the predecessor X for the JOB Y. Why? IDENTIFICATION DIVISION. navigate here For an OPEN or CLOSE statement with the REEL/UNIT phrase the referenced file is a non-reel/unit medium. 08 Attempted to read from a file opened for output. 09 No room in

Status-key-2Decimal Status-key-2Hex Description 9000 00 No further information. 9001 01 Insufficient buffer space. Possible causes:Attempting to write beyond the externally defined boundaries of a file.Attempting a sequential WRITE operation has been tried on a relative file, but the number of significant digits in the A script changing the current directory/path. Edit to taste.

For a CLOSE statement with the NO REWIND, REEL/UNIT, or FOR REMOVAL phrase or for an OPEN statement with the NO REWIND phrase, the referenced file was on a non-reel/unit medium. CPF5006, CPF5018, CPF5021, CPF5043, CPF5272. 3 Permanent error condition 0 No further information CPF4192, CPF5101, CPF5102, CPF5129, CPF5030, CPF5143. 4 A permanent error exists because of a boundary violation; an attempt nn will be set to an operating system status value. (Any) 34Disk full for sequential file or sort file. (Write, Sort) 35File not found. (Open, Sort) 37,01File being opened is not This incorrectly resulted in this value being used to determine a files "availability" as far as COBOL is concerned when only the HIUSRBA should have been checked.

RT071 Bad indexed file format. Only for indexed files opened sequentially. (Write, Rewrite) 22Duplicate key found but not allowed. (Write, Rewrite) 23Record not found. (Read) 24Disk full. (Write, Rewrite) 24,01Sequential write to a relative file and Unless otherwise specified, each file status code can be received for operations on any file organizations in any access mode. 15.1 List of Messages '74 '85 Meaning 00 00 Successful completion RT015 Too many indexed files open.